Bench tool
Reconstitution Calculator
Vial mass and solvent volume in; concentration, draw volume, and the exact barrel graduation out — drawn to scale. A handling reference, not a dosing protocol.
Concentration
—
—
—
—
—
One band is one complete draw. The highlighted band is the draw shown on the barrel.
Awaiting vial mass, solvent volume, and mass per draw.
Figures describe the contents of a vial and the graduation they measure to. Supplied for laboratory research use only. Not a dosing protocol and not medical advice.
Reading a U-100 barrel. Insulin syringes are graduated in units of volume, not International Units: on a U-100 barrel 100 units = 1 mL, so one unit is 0.01 mL. International Units measure biological activity and are not interchangeable with these marks. A 0.3 mL and a 1 mL barrel are about the same physical length — what differs is how many units are printed across it, which is why a smaller barrel resolves a small volume more precisely.
Scope. Every figure here describes the contents of a vial and the graduation that measures them. NHOV compounds are supplied for laboratory research use only. Nothing on this page is a dosing protocol, a schedule, or medical advice, and no figure should be read as a recommendation to administer anything to a human or animal subject.
The arithmetic
How the figures are derived
| Figure | Derivation |
|---|---|
| Concentration (mg/mL) | Vial mass (mg) ÷ solvent volume (mL) |
| Mass per unit (mcg) | Concentration (mg/mL) × 0.01 mL × 1000 |
| Draw volume (mL) | Mass per draw (mg) ÷ concentration (mg/mL) |
| Graduation (units) | Draw volume (mL) × 100 (U-100: 1 mL = 100 units) |
| Complete draws per vial | (Solvent volume − residual hold-up) ÷ draw volume, rounded down |
Notes and limits
- Graduation pitch is a manufacturing convention, not a standard. The figures assume common U-100 barrels print every unit at 0.3 mL and 0.5 mL, and every two units at 1 mL. The barrel in hand is the authority.
- Lyophilised peptide contributes a small volume of its own once dissolved. At the masses and volumes in question this is below the resolution of the marks and is not modelled.
- Residual hold-up defaults to 0.05 mL — solution that cannot be recovered from the vial and needle hub. It is subtracted before counting complete draws.
- Concentration says nothing about solubility or stability. Confirm both for the compound before reconstituting.