Quality Control

The Four Tests Behind Every Batch

One purity reading tells you how clean a sample is. It doesn’t tell you what’s actually in the vial. That’s why every batch clears independent tests for purity, identity and sequence before it ships — plus endotoxin and bioburden where the application calls for it.

A single HPLC reading isn’t enough. It tells you “this peak is 98% of the sample” — but it doesn’t tell you the peak is your peptide. We’ve seen labs ship pure deletion products labelled as the full sequence because they only ran one test and stopped looking. So we run four: purity, identity, sequence, and — where relevant — sterility.

At a glance

Four tests, four different questions

Each one closes a gap the others leave open. Together they confirm not just that a sample is clean, but that it’s actually the molecule on the label.

1. Analytical HPLC

How pure is it? A C18 column separates the sample and the main peak is measured against that product’s release specification — ≥98% for the standard synthetic catalogue.

2. Mass spectrometry

Is it the right molecule? Measured mass is checked against the theoretical mass of the target sequence, to within ±0.1 Da.

3. Sequence verification

Are the amino acids in the right order? Mass alone can be fooled by isobaric substitutions — this confirms the sequence itself.

4. Endotoxin & bioburden

Is it clean enough for sensitive work? LAL and bioburden screening for peptides headed into cell-culture-adjacent or sterile applications.

Where shortcuts show up

Identity and sequence: the two hardest calls

Purity tells you how clean a sample is. These two tests tell you whether it’s actually the peptide you ordered.

Vials prepared for mass spectrometry analysis
Test 2 — Mass Spectrometry

Weighing the molecule, not just eyeballing the peak

Mass spec ionises the peptide and weighs it. The measured mass gets compared against the theoretical mass calculated from the sequence — they should match within ±0.1 Da for our purposes. If they don’t, something went wrong upstream, usually an incorrect amino acid or a side-chain modification we didn’t intend.

We use a Bruker microflex MALDI-TOF for routine work and a Thermo Q Exactive for higher-resolution checks on tricky sequences.

DNA and peptide sequence structure
Test 3 — Sequence Verification

Confirming amino acid order, not just total mass

Mass alone can be fooled by isobaric substitutions — two amino acids with the same mass in different positions. Sequence verification confirms the actual amino acid order. For most peptides we use LC-MS/MS fragmentation; for older Edman-suitable sequences (typically under 30 residues, without N-terminal modifications) we run Edman degradation instead.

Either way, the output is a sequence list that gets compared directly to the published structure of the target peptide.

Methodology

How each test is run

The equipment and pass standard behind every result that ends up on your certificate of analysis.

TestWhat it checksMethod & equipmentPass standard
1. Analytical HPLCPurity of the sampleAnalytical C18 column, Agilent 1260Main peak ≥98% of total area for standard synthetic peptides; long, recombinant, gonadotropin and extract products carry their own stated specification — full method on Purity Standards
2. Mass spectrometryIdentity of the moleculeBruker microflex MALDI-TOF (routine); Thermo Q Exactive (high-resolution)Measured mass within ±0.1 Da of theoretical
3. Sequence verificationAmino acid orderLC-MS/MS fragmentation, or Edman degradation for shorter sequencesSequence matches the published structure
4. Endotoxin & bioburdenSterility / cleanliness for sensitive useLAL endotoxin assay and bioburden screenResult reported in EU/mg — run on request and for flagged products; the COA shows whether it was performed

Zero tolerance

What a failed batch actually gets

Destroyed. That’s it. We don’t downgrade a failed batch, don’t blend it with better material, don’t quietly sell it to bulk distributors, and don’t relabel it as a different product. Failed batches are removed from inventory and physically destroyed, with the destruction logged in the batch dossier.
Seven-year retention. Every QC document tied to a batch — every chromatogram, every mass spec readout, every sequence file — is archived for seven years. If you bought a vial in 2024 and want the dossier in 2031, we can still pull it. Email [email protected] with your batch number.

Every batch tested, every method stated, seven years on file.

Browse verified peptides or pull the full dossier for a batch you already have.

Shop tested peptides →